The use of quartz cuvette is not always necessary and it is dependent on the wave length range been targeted. The transmission rate for quartz cuvette is high (83% or higher) @ UV length range whereas plastic (PS or PMMA) or Optical glass don't.
When organic solvents are used, glass or quartz are preferable because the corvettes display higher resistance when compared to others made from plastic. Generally, quartz cuvette can be used over and over and the display higher transparency and accuracy of measurement.
Unique Technological Expertise For Exact Measurement and Precise Results
Micro/Semi/Macro Volume | Lid/Stopper/Screw Cap |
Spectrophotometer Cuvettes | Fluorometer Cuvettes |
Single/Dual/Demountable | Tailored Requirements |
Flow-Through Cells | Custom Cuvettes |
The AirekaCells quartz cuvettes are designed to hold liquid solution samples. The material ES quartz glass has high transmission rate at UV wavelength range low to 190nm, and excellent performance under visible light range. With IR quartz, you can expect to work with a range up to 3500nm, which covers infrared light testing experiments perfectly.
Our quartz cuvettes are either two windows clear, for use in absorption spectroscopy experiments, or four windows clear, for use in fluorescence spectroscopy. The cuvettes can be cleaned using standard cleaning procedures.
For different budgets and sealing requirements, different spectroscopy cuvette caps are available. To block dust and particles a Teflon lid is used, while a Teflon stopper or screw cap is used to prevent evaporation and ensure strict sealing purpose. The silicon lid is also useful for the balance of sealing and its cost effectiveness as shown below.
Type | Material | Sealing Strength | Injection |
---|---|---|---|
PTFE Lid | PTFE | ★☆☆☆☆ | NO |
Silicone Lid | Silicone | ★★★☆☆ | NO |
Silicone Lid w Hole | Silicone | ★★★☆☆ | Syringe Needle Injection |
PTFE Stopper Cap | PTFE | ★★★★☆ | NO |
PTFE Screw Cap with Septa | PTFE | ★★★★★ | NO |
PTFE Screw Cap with Hole | PTFE | ★★★★★ | Syringe Needle Injection |
The standard 10mm transmission path length of AirekaCells quartz cuvettes with an outer dimension of 12.5x12.5mm is compatible with most of the spectrophotometers in the market. Sub-micro, semi-micro and macro cuvettes are available, which usually sold with a minimum of 2pcs however a single piece MOQ is also negotiable by request.
Above the specified, a wider range of cuvettes for use in spectroscopy and cytometry with optical path lengths spanning 0.1 to 100mm are listed with stock.
The sub-micro and micro cuvettes are usually fitted with glue. These cuvettes should not be used together with Benzene, toluene, aqua Regis, ethanol, corrosive solutions, or other similar substances, as they may degrade the bonds between the pieces and cause leakage in the cuvettes. Use with Aqueous samples and Organic solvents should not be used for glued types.
On the other hand, other cuvettes are fused as one piece and are resistant to corrosive chemicals and high temperatures. When properly cleaned, they don't cause and cross contamination or leakage.
Corrosive and High-Temperature Resistant Cuvettes
Browse A List of Stock Cuvettes: https://airekacells.com/cuvettes
1. UV-vis Spectrophotometer ES Quartz Cuvettes, 2 Windows Polished
Check A LIST of 4 Windows Clear Fluorometer Quartz Cuvettes
Our ES quartz cuvettes with high transmission between 190nm and 2500nm, are ideal for working within UV- visible spectrum.
The IR quartz cuvettes with high transmission between 220nm and 3500nm, offer excellent transmittance across the near - IR, and mid- IR spectra.
When transmission values of cuvettes are been compared it is essential to ensure that same measurement conditions are put in place. Also note that the transmission curves shown we're plotted using measurements taken from empty cuvettes (2 windows).
MORE INFORMATION ABOUT CUVETTE MATERIALS: https://airekacells.com/blog/cuvette-guide
.
The optical path length of a cuvette is the distance of light that goes through the interior walls of a cuvette.
On a standard spectrometer cuvette, the light path or path length will be the inner distance from the front window to the back window. The standard cuvette optical path length is 10mm.
The standard 10mm transmission path length of AirekaCells quartz cuvettes with an outer dimension of 12.5x12.5mm is compatible with most of the spectrophotometers in the market. Sub-micro, semi-micro and macro cuvettes are available, which usually sold with a minimum of 2pcs however a single piece MOQ is also negotiable by request.
Standard rectangular cuvettes (quartz cells) are the most commonly used type in chemical analysis. The exterior dimension 45×12.5×12.5mm makes it possible for the Cuvettes to be used with virtually every spectrophotometer and photo meter instrument currently in use.
QG10004-2, Fused1 Quartz Cuvette | QG10014-2, Fused1 Quartz Cuvette | QG10744-2, Fused1 Quartz Cuvette |
3.5mL, 2 Windows Clear, UV-vis | 3.5mL, 2 Windows Clear, UV-vis | 3.5mL, 2 Windows Clear, UV-vis |
Path Length: 10mm, Width: 10mm | Path Length: 10mm, Width: 10mm | Path Length: 10mm, Width: 10mm |
Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm |
ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm |
PTFE Lid (Optional: Silicone Lid) | PTFE Stopper (Good Sealing) | PTFE Screw Cap (Air Tight Seal) |
Cap Hole for Injection Available |
| Cap Hole for Injection Available |
These cuvettes have an exterior height of 45mm, two clear windows and an open top. The cuvettes' walls and the bottom are smooth on the inside. On the outside, the light path windows are clear while the adjacent windows and the bottom are frosted. Typically, windows are 1.25mm thick and each cuvette in this range is supplied with a PTFE cover.
QG19004-2, Fused1 Quartz Cuvette | QG10744-2C, Fused Quartz Cuvette | QG10704-2, Fused1 Quartz Cuvette |
3.5mL, 2 Windows Clear, UV-vis | 3.5mL, 2 Windows Clear, UV-vis | 3.5mL, 2 Windows Clear, UV-vis |
Path Length: 10mm, Width: 10mm | Path Length: 10mm, Width: 10mm | Path Length: 10mm, Width: 10mm |
Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm |
ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm |
Silicone Lid (Good Sealing) | PTFE Screw Cap (Air Tight Seal) | No Cap |
Cap Hole for Injection Available | Cap Hole for Injection Available | OD: 8mm, Overall Length: 120mm |
Full List of 10mm Standard Cuvettes>>
Since these cuvettes only have two windows clear (polished windows), they are not ideal for use in fluorescence spectroscopy where it is necessary to have four windows clear (polished windows) to allow measurement of the fluorescence at right angles to the beam path. AirekaCells offers fluorometer cuvettes with four windows clear.
QG16360-2, Fused Quartz Cuvette | QG16310-2, Fused Quartz Cuvette | QG10124-2, Glued Quartz Cuvette |
350uL/ 700uL/ 1000uL/ 1.4mL/ 1.7mL | 350uL/ 700uL/ 1000uL/ 1.4mL/ 1.7mL | 350uL/ 700uL/ 1000uL/ 1.4mL/ 1.7mL |
2 Clear Windows, White Wall | 2 Clear Windows, White Wall | 2 Clear Windows, Black Wall |
Path Length: 10mm | Path Length: 10mm | Path Length: 10mm |
Width: 1/2/3/4/5mm | Width: 1/2/3/4/5mm | Width: 1/2/3/4/5mm |
Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm |
ES2 Quartz: 190nm- 2500nm | ES2 Quartz: 190nm- 2500nm | ES2 Quartz: 190nm- 2500nm |
PTFE Lid | PTFE Stopper | PTFE Lid |
Full List of 10mm Semi-Micro Cuvettes>>
Due to the small volume of our capacity starting from 0.35ml, our range of cuvettes is perfect for researchers who have limited quantities of samples or solutions. These fluorescence cuvettes enable you to use the minimum amount of solution, hence, you can conduct more experiments than you would normally be able to.
1.1.3 Sub-Micro 10mm Path Length Cuvette, <350uL
QG15100-2, Glued Quartz Cuvette | QG15101-2, Glued Quartz Cuvette | QG16300-4, Glued Quartz Cuvette |
20/50uL/100uL | 100uL/200uL | 100uL |
2 Clear Windows, Black Wall | 2 Clear Windows, Semi-Black Wall | 2 Clear Windows, White Wall |
Path Length: 10mm | Path Length: 10mm | Path Length: 10mm |
Window: 2*1mm or 1*5mm 2*5mm | Window: 2*5mm or 2*10mm | Window: 2*5mm |
Z dimension: 8.5/15/20mm | Z dimension: 8.5/15/20mm | Z dimension: 8.5/15/20mm |
Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm |
ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm |
PTFE Lid | PTFE Lid | PTFE Lid |
Full List of 10mm Ultra Micro Cuvettes>>
Note: These glued cuvettes should not be worked with on benzene, toluene, aqua regia, ethanol, corrosive solutions, or other similar substances, as they may degrade the bonds between the pieces, hence causing leakage in the cuvette.
About Z dimension:
The Z dimension of a spectroscopy cuvette/cell is the distance from the bottom of the cuvette to the center of the sample window or aperture (the area through which the light passes).
Z dimension is usually used with small volume cuvettes or flow-through cells when there is a restricted area window aperture.
Above the 10mm standard quartz cuvettes, a wider selection of cuvettes for use in spectroscopy and cytometry with optical path lengths spanning 0.1 to 100mm and above are also listed with stock.
When samples with high absorption coefficents that are too high for a standard 10mm path length cuvette, other types with path Lengths as short as 1mm are available. You may have a ten-times reduction in absorbance by simply swapping cuvettes, rather than diluting samples hence wasting time and solvent.
Cuvettes of 1mm/2mm/3mm/4mm/5mm are listed below:
1mm Quartz Cuvette
Various solutions whose absorption coefficients are too high for a standard path length cuvette, we have cuvettes with path lengths as short as 1mm. You can achieve a ten-times reduction in absorbance by simply swapping the cuvettes other than diluting the solutions and then wasting your time and solvent.
QG10001-2, Fused1 Quartz Cuvette | QG10011-2, Fused1 Quartz Cuvette | QG16410-2, Fused1 Quartz Cuvette |
350uL, 2 Windows Clear, UV-vis | 350uL, 2 Windows Clear, UV-vis | 350uL, 2 Windows Clear, UV-vis |
Path Length: 1mm, Width: 10mm | Path Length: 1mm, Width: 10mm | Path Length: 1mm, Width: 10mm |
Outer Size: 45x12.5x3.5mm | Outer Size: 45x12.5x3.5mm | Outer Size: 45x12.5x3.5mm |
ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm |
PTFE Lid (Optional: Silicone Lid) | PTFE Stopper (Good Sealing) | PTFE Screw Cap (Air Tight Seal) |
QG10012-2, Fused1 Quartz Cuvette | QG10003-2, Fused1 Quartz Cuvette |
700uL, 2 Windows Clear, UV-vis | 1.7mL, 2 Windows Clear, UV-vis |
Path Length: 2mm, Width: 10mm | Path Length: 5mm, Width: 10mm |
Outer Size: 45x12.5x4.5mm | Outer Size: 45x12.5x7.5mm |
ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm |
PTFE Stopper (Good Sealing) | PTFE Lid |
Full List of Short Path Length Cuvettes
1.3 Quartz Cuvettes Optical Path Length>10mm Macro Quartz Cuvette Path Length of 20/25/30/40/50/100mm
QG10005-2, Fused1 Quartz Cuvette | QG10006-2, Fused1 Quartz Cuvette | QG10007-2, Fused1 Quartz Cuvette |
7mL, 2 Windows Clear, UV-vis | 10.5mL, 2 Windows Clear, UV-vis | 14mL, 2 Windows Clear, UV-vis |
Path Length: 20mm, Width: 10mm | Path Length: 30mm, Width: 10mm | Path Length: 40mm, Width: 10mm |
Outer Size: 45x12.5x22.5mm | Outer Size: 45x12.5x32.5mm | Outer Size: 45x12.5x42.5mm |
ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm |
Include PTFE Lid | Include PTFE Lid | Include PTFE Lid |
Full List of 2 Windows Macro Cuvettes>>
ALL-Quartz 4 Windows Clear Cuvettes Ideally Suited for Fluorescence and Flow-Through Spectroscopic Analysis
Check A LIST of 2 Windows Clear Spectrophotometer Quartz Cuvettes
It’s not necessary to always use quartz cuvettes and it depends on the wavelength range you are targeting. Quartz cuvettes have a high transmission rate (80% or higher) @ UV wavelength range while Optical Glass or Plastic (PS or PMMA) don’t.
If organic solvents are involved, glass or quartz cuvettes are the preferred choices as these cuvettes display higher resistance compared to variants made from plastic. In general, quartz cuvettes display greater transparency and accuracy of measurement, and they can be re-used many times.
Unique Technological Expertise For Exact Measurement and Precise Results
2. Fluorometer/ Fluorescence Quartz Cuvettes, 4 Windows Polished
The most commonly used type of Cuvette in chemical analysis is Standard rectangular cuvettes (quartz cells). It has an exterior dimension of 45×12.5×12.5mm which allows the cuvettes to be used with virtually every spectrophotometer and photo meter instrument currently in use.
These cuvettes have an exterior height of 45mm, two clear windows and an open top. Inside the walls of the cuvette and the bottom are made smooth. On the outside, the light path windows are clear while the adjacent windows and the bottom are frosted. Typically, windows are 1.25mm thick and each cuvette in this range is supplied with a PTFE cover.
QG10204-4, Fused1 Quartz Cuvette | QG10214-4, Fused1 Quartz Cuvette | QG10744-4, Fused1 Quartz Cuvette |
3.5mL, 4 Windows Clear | 3.5mL, 4 Windows Clear | 3.5mL, 4 Windows Clear |
Path Length: 10mm, Width: 10mm | Path Length: 10mm, Width: 10mm | Path Length: 10mm, Width: 10mm |
Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm |
ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm |
PTFE Lid (Optional: Silicone Lid) | PTFE Stopper (Good Sealing) | PTFE Screw Cap (Air Tight Seal) |
Cap Hole for Injection Available |
| Cap Hole for Injection Available |
In fluorescence spectroscopy experiments , Fused Quartz Cuvettes with four windows clear(polished sides) are used. The four polished windows allow measurement of the fluorescence at right angles to the beam path and standard cleaning procedure should be used for cleaning.
QG10744-4C, Fused Quartz Cuvette | QG10814-4, Fused1 Quartz Cuvette | QG10704-4, Fused1 Quartz Cuvette |
3.5mL, 4 Windows Clear | 3.5mL, 4 Windows Clear | 3.5mL, 4 Windows Clear |
Path Length: 10mm, Width: 10mm | Path Length: 10mm, Width: 10mm | Path Length: 10mm, Width: 10mm |
Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm |
ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm |
PTFE Screw Cap | PTFE Lid | No Lid or Cap |
2mm Cap Hole for Injection | 5 Sides Clear | OD: 8mm, Overall Length: 120mm |
Full List of 10mm Standard Fluorometer Cuvettes>>
Despite these cuvettes been designed for use in fluorescence, the through-beam windows can be used independently for other spectroscopic applications. AirekaCells also offers cuvettes with two windows clear (polished sides) and two frosted sides specifically designed for these other applications. (check here).
QG10234-4, Fused Quartz Cuvette | QG16150-4, Glued Quartz Cuvette | QG16480-4, Fused Quartz Cuvette |
350uL/700uL/1000uL/1.4mL/1.7mL | 350uL/700uL/1000uL/1.4mL/1.7mL | 350uL/700uL/1000uL/1.4mL/1.7mL |
2 Clear Windows, White Wall | 2 Clear Windows, White Wall | 2 Clear Windows, Black Wall |
Path Length: 10mm | Path Length: 10mm | Path Length: 10mm |
Width: 1/2/3/4/5mm | Width: 1/2/3/4/5mm | Width: 1/2/3/4/5mm |
Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm |
ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm |
PTFE Lid | PTFE Stopper | PTFE Stopper |
Full List of Semi-Micro 4 Windows Cuvettes>>
Due to the small volume of our capacity starting from 0.35ml, our range of cuvettes is perfect for researchers who have limited quantities of samples or solutions. These fluorescence cuvettes enable you to use the minimum amount of solution, hence, you can conduct more experiments than you would normally be able to.
QG15100-4, Glued Quartz Cuvette | QG15050-4, Glued Quartz Cuvette | QG10310-4, Fused Quartz Cuvette |
100uL | 50uL | 110uL |
3 Clear Windows, Black Wall | 3 Clear Windows, Semi-Black Wall | 4 Clear Windows, White Wall |
Path Length: 10mm | Path Length: 10mm | Path Length: 10mm |
Window: 2*5mm | Window: 1*5mm |
|
Z dimension: 8.5/15/20mm | Z dimension: 8.5/15/20mm |
|
Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm | Outer Size: 10x6.5x6.5mm |
ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm |
PTFE Lid | PTFE Lid |
|
Full List of Ultra Micro Fluorescence Cuvettes>>
Note: These glued cuvettes should not be used with benzene, toluene, aqua regia, ethanol, corrosive solutions, or other similar substances, as they may degrade the bonds between the pieces and cause the cuvette to leak.
About Z dimension:
The Z dimension of a spectroscopy cuvette/cell is the distance from the bottom of the cuvette to the center of the sample window or aperture (the area through which the light passes). Z dimension is usually used with small volume cuvettes or flow-through cells when there is a restricted area window aperture.
Short and Dual Path Length Quartz Cuvettes
For solutions with absorption coefficients that are too high for a standard path length cuvette, we have cuvettes with path lengths as short as 1mm. You can achieve a ten-times reduction in absorbance by simply swapping cuvettes, rather than wasting time and solvent by needing to dilute your solutions.
QG10203-4, Fused1 Quartz Cuvette | QG10213-4, Fused1 Quartz Cuvette | QG19310-4, Fused1 Quartz Cuvette |
0.7/1.0/1.7mL, 4 Windows Clear | 1.7mL, 4 Windows Clear | 0.7/1.0/1.7mL, 4 Windows Clear |
Path Length: 2/3/5mm, Width: 10mm | Path Length: 5mm, Width: 10mm | Path Length: 2/3/5mm, Width: 10mm |
Outer Size: 45x12.5x7.5mm | Outer Size: 45x12.5x3.5mm | Outer Size: 45x12.5x7.5mm |
ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm |
PTFE Lid | PTFE Stopper (Good Sealing) | PTFE Screw Cap (Air Tight Seal) |
Full List of Short Path Length Cuvettes>>
We have a series of 4 window clear cuvettes which can be used for short and long path lengths simultaneously. For example, a 0.7ml volume cuvette with a path length of 2mm and a standard 10mm all rolled into a single piece. Simply put, the path length to be used is dependent on how you put the cuvette in your spectrophotometer. If the light beam enters through the front window, then you have a 10mm path length cuvette. Whereas, if the cuvette is rotated 90 degrees you have a 2mm path length.
Single/Dual Channel Flow Cuvettes
These flow-through cells with a narrow channel. Excellent for microscope-based spectroscopic analyses.
QG10650-2, Fused1 Quartz Cuvette | QG10380-2, Glued Quartz Cuvette | QG16200-F, Glued Quartz Cuvette |
350/700uL, 2 Windows Clear | 16uL | 150uL |
Path Length: 1 or 2mm | Path Length: 0.2mm | Path Length: 0.5mm |
Outer Size: 3.5 or 4.5x85x12.5mm | Outer Size: 4x75x25mm | Outer Size: 3x12.5x45mm |
ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm |
Tube OD: 3mm, ID: 1.5mm | Dual-Channel |
|
30% OFF Now | 30% OFF Now | 30% OFF Now |
The Flow cells are used to allow the sample to pass through the cell and they are connected to the sample source via tubing. Long path length flow cells are useful for low concentration samples and need long path length, rectangular cell holder.
QG10500-2, Fused1 Quartz Cuvette | QG10470-2, Fused Quartz Cuvette | QG16210-F, Fused Quartz Cuvette |
860uL, 2 Windows Clear | 3.5mL, 2 Windows Clear | 3.5mL, 4 Windows Clear |
Path Length: 1mm, Width: 21mm | Path Length: 10mm, Width: 10mm | Path Length: 10mm, Width: 10mm |
Outer Size: 45x25x4mm | Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm |
ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm |
Full List of Flow-Through Cuvettes>>
QG10670-2, Fused1 Quartz Cuvette | QG10680-2, Fused Quartz Cuvette | QG10370-2, Glued Quartz Cuvette |
10uL | 25uL | 16ul |
Path Length: 0.2mm, Width: 10mm | Path Length: 0.5mm, Width: 10mm | Path Length: 0.2mm, Width: 20x4mm |
Outer Size: 2.6x12.5x45mm | Outer Size: 2.9x12.5x45mm | Outer Size: 4x30x15mm |
ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm |
Full List of Demountable Cuvettes>>
QG10614, Glued Quartz Cuvette | QG15082-3, Glued Quartz Cuvette | QG15627-2, Glued Quartz Cuvette |
32uL, 3 Windows Clear | 100uL, 3 Windows Clear | 400uL, 2 Windows Clear |
Path Length: 10mm | Path Length: 10mm | Path Length: 10mm |
Z dimension: 8.5mm or 15mm | Z dimension: 8.5mm or 15mm | Z dimension: 8.5mm or 15mm |
Outer Size: 45x12.5x12.5mm | Outer Size: 45x12.5x12.5mm | Outer Size: 35x12.5x12.5mm |
ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm | ES2 Quartz: 190nm-2500nm |
Full List of Customized and Flow-Through Cuvettes>>
UV-vis quartz cuvettes are designed to hold solution samples for spectroscopic experiments. Quartz cuvettes with 2 clear windows for absorption spectroscopy and quartz cuvettes with 3 or 4 clear windows (polished sides) for fluorescence spectroscopy are available with AirekaCells.
We have quartz cuvettes (some ultra or semi micro-volume cuvettes are glued) in stock which are fused cuvettes, suitable for wavelength 190nm~2500nm. We can also supply IR fused quartz cuvettes for 220nm~3500nm and optical glass cuvettes for 340nm- 2500nm. Macro, semi-micro and ultra-micro volume sizes are all available.
Besides the in-stock UV-vis quartz cuvettes listed below, many customized cuvettes are supplied to our clients. Please specify your material and dimension requirements by either sending us an email sales@airekacells.com or leave a message by live chat below. We will be more than happy to help you with your tailored needs.
All our in-stock UV-vis fused quartz cuvettes are made by a diffusion bonding method. Quartz is heated to a high temperature and then adhered together by applying pressure. UV-vis quartz cuvettes made in such a method have much stronger chemical and high-temperature resistance.
When high concentration samples are been used, the solution is diluted and this will allow for spectrophotometry measurement with a 10mm path length cuvette. However, there are samples that cannot be easily diluted. For instance, due to interaction with the solvent, some samples cannot be diluted as this will cause a change in the absorbance (i.e. shift in the peak wavelengths)
In these cases when absorbance is high and the dilution of the solution is difficult " short path length cuvettes" is effective. Short path length cuvettes with optical path lengths of 1mm, 2mm, 3mm and 5mm are available. The results obtained by analyzing toluene with a 1mm quartz cuvette and a 10mm ones indicates that there is much less absorption saturation with the 1mm cuvette than there is with the 10mm cell.
Solution analysis in the infrared region is a well-known application of measurement using a short path length cuvette. when 10mm cuvette is used for measurement in the near infrared region, saturation often occurs due to absorption by the solvent, making it difficult to ascertain the absorption of the sample. A short path length cuvette is used to prevent absorption saturation due to the solvent.
The optical path length of the cell is selected based on the size of the absorbance or transmittance of a low or high concentration chemical samples.
Browse a List of Short Path Length Cuvettes>>
What are “long path length” cuvettes and why are they used? (sample too diluted)
For different solution analyses Cuvettes with a standard optical path length of 10mm are used. However, if the sample concentration is low, it may not be possible to obtain enough absorbance using a quartz of all this size. Although, concentrating the sample will allow for the use of 10mm cuvette, concentrating is a difficult in instances when the sample vaporizes or undergoes a chemical change during the concentration process.
In such instances, measurements using a "long path length" is effective. Long path length Cuvettes with optical path lengths of 20mm, 30mm, 40mm, 50mm and 100mm are used. The absorbance increases proportionately to the cuvettes’ optical path length. Results obtained when 10-mg/L potassium permanganate solution was analyzed with a 10mm cuvette and a 100m one shows that the absorbance of the 100m cuvette is ten times that of the 10mm cell.
Turbidity measurement of water is a well-known application of analysis using a long path length cuvette. 50mm and 100mm cells are used to analyze samples with low turbidity.
Browse a List of Long Path Length Cuvettes>>
Why is it important not to have fingerprints on the cuvette?
To avoid interference, finger prints should not be made on the Cuvettes so as to ensure full light absorption in the Spectrophotometer. This produces accurate readings of the absorbance.
It is important to align the cuvette in the sample holder each time so as to ensure that the dimensions of the wall is not different as this may affect the intensity of light passing through the cuvette. Aligning consistently help to achieve accurate readings for absorbance.
To the best of our knowledge, the technical information provided here is accurate. However, AirekaCells assumes no liability for the accuracy of this information. The values provided here are typical at the time of manufacture and may vary over time and from batch to batch.
Brand | AirekaCells® | Polished Side | 4 Windows |
Part No. | QG10744-4 | Wavelength Used | 190-2500nm |
Path Length | 10 mm | External Size | 12.5 x 12.5 x 45 mm |
Inside Width | 10 mm | Transmission | > 83% @ 200 nm |
Volume | 3.5 mL | Fused | High Temp. Fused |
Material | ES Quartz Glass | Price UOM | One Piece Price |